Pennsylvanias statewide building code is generally known as the Uniform Construction Code (UCC). However, there are a number of rules of thumb when setting out to build a new deck. Act 35 of 2017 and Act 36 of 2017 went into effect October 25, 2017. Traditionally, the ICC has published fire and smoke protection features for elevator lobbies in Chapter 7 of the IBC. 45 of 1999, which is also commonly referred to as the Uniform Construction Code (UCC). rules and regulations under the Local Health Administration Law (16 P.S. For SI:1 foot = 304.8 mm; 1 inch = 25.4 mm; 1 pound per square foot per foot = 0.1571 kPa, For SI: 1 foot = 304.8 mm; 1 inch = 25.4 mm; 1 pound per square foot per foot = 0.1571 kPa. You also have the option to opt-out of these cookies. 5 0 obj Here in Pennsylvania, permit and inspection requirements for decks vary from municipality to municipality. Installing any deck that is more than 30" above ground level at any point around the perimeter . Payment (Residential Building Permit Fees): Payment in full must be made before we can release the Permit or perform any inspections. Table R507.5. Refer to, Unbalanced backfill height is the difference in height between the exterior finish ground level and the lower of the top of the. The Department also has sole jurisdiction for all elevators and all state-owned buildings, no matter where they are located. Please accept to continue using the site. A listing of all of Pennsylvania's municipalities and their decisions regarding local enforcement of the UCC can be accessed below by clicking on the link entitled "Municipal Elections and Contact Information" (under the "Local Enforcement" header). For example, if the footings of your deck are not deep enough, you will have to remove large sections of the deck so that the footings can be replaced. requirements. Chapter 4 Special Detailed Requirements Based on Occupancy and Use. Enforcement of the UCC began in April 2004. The IBC requires 42" high guardrails. See Table R403.3(1) for required dimensions and. It is the responsibility of the owner to ensure all required inspections are completed and approved. Borough of Bellevue handles residential, including decks and . So if youre ready to build the deck of your dreams, dont do it alone. Not only can a fire destroy your home or property, but it can also spread to neighbors, thus putting those who had no say in your decks construction at risk. That may require replacing a particular section or you may need to remove the construction entirely. approved code agency in a current evaluation report. International Building Code 2018 (IBC 2018) Change Code. Accessibility, 311
Contact Sales. 4 bar at the top and the bottom of the footing. General Notes . Minimum nominal thickness for plain masonry foundation, The minimum actual thickness of a load-bearing masonry wall shall be not less than 4 inches (102 mm) nominal or 3, Piers shall be constructed in accordance with, The maximum height of a 4-inch (102 mm) load-bearing masonry foundation wall supporting wood-frame, The unbalanced fill for 4-inch (102 mm) foundation, Plywood shall be of the following minimum, Where a major portion of the wall is exposed above ground and a better appearance is desired, the following plywood, Structural I A-C, Structural I B-C or Structural I C-C (Plugged) in accordance with DOC PS 1, A-C Group 1, B-C Group 1, C-C (Plugged) Group 1 or MDO Group 1 in accordance with DOC PS 1, Single Floor in accordance with DOC PS 1 or DOC PS 2. Interior covering. When the height of fill is more than 12 inches (305 mm) above the interior, For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per cubic foot = 0.1572 kN/m, Wood sill plates shall be a minimum of 2-inch by 4-inch (51 mm by 102 mm) nominal lumber. These pages provide information regarding Pennsylvania's statewide building code, generally known as the Uniform Construction Code (UCC). See Section R402.2 for maximum cementitious materials content. The bottom surface of footings shall not have a, The placement of buildings and structures on or adjacent to, On graded sites, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge or the inlet of an, Alternate setbacks and clearances are permitted, subject to the approval of the, Foundation and floor slabs for buildings located on expansive soils shall be designed in accordance with. Here in Pennsylvania, permit and inspection requirements for decks vary from municipality to municipality. Deck joists shall be permitted to cantilever not greater than onefourth of the actual, adjacent joist span. Concentrated loads and their points of application; The percolation rate for good drainage is over 4 inches per hour, medium drainage is 2 inches to 4 inches per hour, and poor is less than 2 inches per hour. The Pennsylvania Construction Code Act (Act 45 of 1999) established a State building code, the Uniform Construction Code (UCC), that must be complied with in all Pennsylvania jurisdictions. Permits are the best way to ensure that you do not have to navigate a family tragedy or expensive legal and insurance fees down the road. Further, these kinds of details will come under close scrutiny whenever you put your home on the market. This regulationbecame permanent upon approval by theIndependent Regulatory Review Commission on December 6, 2018. For SI: 1 pound per square foot = 0.0479 kPa. All load-bearing lumber shall be identified by the, For wood foundations that are not designed and installed in accordance with AF&PA PWF, the height of backfill against a foundation wall shall not exceed 4 feet (1219 mm). Here are some things to keep in mind if you are either considering moving forward without a permit or need to get a permit for a deck thats already been completed. Permits ensure that your deck is structurally sound. Forty-mil (1 mm) polymer-modified asphalt. This is definitely not one of those situations when you want to ask forgiveness rather than permission. PA UCC Reference: Title 34, Chapter 401.21(7)(iii)(L)-new section PA UCC Reference: Title 34, Chapter 401.21(7)(iii)(W)-new figure InternationalCode Council(ICC). If you put your home on the market, all of the records of building projects will be put on display. fences _____ Sample List of Code Violations: Multifamily Dwellings . The remainder of the excavated area shall be backfilled with the same type of soil as was removed during the excavation. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12 gage [0.105 inch (3 mm)] shank with a minimum 3 / 8-inch (10 mm) diameter head, ASTM F 1667, of a length to penetrate through the roofing materials and a minimum of 3 / 4 inch (19 mm) into the roof sheathing. Certified third party agencies hired by property owners (or their contractors) enforce the residential requirements of the UCC in all opt-out municipalities. As such, effective immediately, you must cease all enforcement of the 2021 accessibility standards. For questions about the lighting at the City-County Building, please reach out to the Office of the Mayor. Plan Analyst for the 2018 IBC and Plan Analyst for the 2018 IRC simplifies the plan review / code study process enabling compliance to specific code years. Part III Building Planning and Construction, Chapter 13 General Mechanical System Requirements, Chapter 14 Heating and Cooling Equipment and Appliances, Chapter 19 Special Appliances, Equipment and Systems, Chapter 22 Special Piping and Storage Systems, Chapter 37 Branch Circuit and Feeder Requirements, Chapter 39 Power and Lighting Distribution, Chapter 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits, Appendix A Sizing and Capacities of Gas Piping, Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances, and Appliances Listed for Use With Type B Vents, Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems, Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation, Appendix E Manufactured Housing Used as Dwellings, Appendix G Piping Standards for Various Applications, Appendix J Existing Buildings and Structures, Appendix T Recommended Procedure for Worst-Case Testing of Atmospheric Venting Systems Under N1102.4 or N1105 Conditions 5ACH, Appendix U Solar-Ready ProvisionsDetached One- And Two-Family Dwellings, Multiple Single-Family Dwellings (Townhouses), Section N1102 (R402) Building Thermal Envelope, Section R310 Emergency Escape and Rescue Openings, Section R312 Guards and Window Fall Protection. All lumber and plywood shall be pressure-preservative treated and dried after treatment in accordance with AWPA U1 (Commodity Specification A, Use Category 4B and Section 5.2), and shall bear the. Users of Plan Analyst in Pennsylvania have included: Building and Residential Code Resources in Pennsylvania There are multiple ICC Chapters in Pennsylvania, Pennsylvania code adoption status on the ICC website. 1st deck RAILINGS WHAT YOU NEED TO KNOW 36 "minimum height when surface is 30" + above grade <> Where applicable, the depth of footings shall also conform to Sections, Except where otherwise protected from frost, foundation. Commercial decks attached to multi-family buildings, such as apartment buildings or businesses, are regulated under the International Building Code (IBC). and to make any changes it deems necessary if the These cookies do not store any personal information. For SI: 1 inch = 25.4 mm, 1 pound per square inch = 6.895 kPa. Joints of the vapor retarder shall overlap by 6 inches (152 mm) and shall be sealed or taped. Wall construction shall be in accordance with either Table R404.1.1(2), Table R404.1.1(3), Table R404.1.1(4), or a design shall be provided. Pennsylvania UCC states that Permits must be issued within 15 working days if not returned to the applicant for additional changes or information. But opting out of some of these cookies may have an effect on your browsing experience. Uniform Construction Code Construction in Pennsylvania, including the City of Pittsburgh, is regulated by the Pennsylvania Construction Code Act or PA Act No. Building 5. Search a chapter, section, or keyword in the search bar. See "Codes and Standards Enforced Under the UCC" below for information about which version of the triennial codes applies to your construction project. No inspections can be performed until the Permit has been paid for in full. Essentially, you will need to apply as if the building was never completed. Where splices are necessary in reinforcement, the length of lap splice shall be in accordance with Table R611.5.4. General Construction . Online Shelter Permit
For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kPa. Where the bar used is. The maximum anchor bolt spacing shall be 4 feet (1219 mm)for buildings over two, Where continuous wood foundations in accordance with. The Regulations will be updated to reflect these changes in approximately 60 days. Pennsylvania has rules governing building construction which apply throughout the state. An improperly installed deck could collapse or could be a serious fire hazard. Adams, Dickey, Golden Valley, Hettinger, LaMoure, Oliver, Ransom, Sargent, Sioux, Ashland, Crawford, Defiance, Holmes, Huron, Knox, Licking, Morrow, Paulding, Putnam, Richland, Seneca, Williams, Berks, Blair, Bradford, Cambria, Cameron, Centre, Clarion, Clearfield, Clinton, Crawford, Elk, Forest, Huntingdon, Indiana, Jefferson, Lackawanna, Lycoming, McKean, Pike, Potter, Susquehanna, Tioga, Venango, Warren, Wayne, Wyoming, Bennett, Custer, Fall River, Lawrence, Mellette, Shannon, Todd, Tripp, Bon Homme, Charles Mix, Davison, Douglas, Gregory, Jackson, Jones, Lyman, Beadle, Brookings, Brown, Campbell, Codington, Corson, Day, Deuel, Edmunds, Faulk, Grant, Hamlin, Kingsbury, Marshall, McPherson, Perkins, Roberts, Spink, Walworth, Carbon, Daggett, Duchesne, Rich, Sanpete, Uintah, Wasatch, Addison, Chittenden, Franklin, Orange, Washington, Windsor, Kenosha, Kewaunee, Racine, Sheboygan, Walworth. This record will be useful as potential home buyers want proof of the legitimacy and quality of deck constructions. Act 35 of 2017 and
Press Releases
Permits are in place to ensure the safety of you, your family, your guests, and your neighborhood. Chapter 11, Appendix E of the International Building Code of 2018 and any other accessibility requirements contained in the 2018 I-codes referenced by the Uniform Construction Code were published in the Pennsylvania Bulletin and became effective on June 15, 2019. You may be trying to access this site from a secured browser on the server. That way, you can feel confident in the safety of your deck and in the resale value of your home. This guide includes tables for sizing all structural elements including footings. %PDF-1.3 Chapter 2 Definitions. Here are a few things you can expect to encounter: There are codes in place to ensure that you are being a good neighbor and not infringing on the property rights of those adjacent to you. Most permits require at least simple plans to verify the legitimacy of your proposed work. The porous fill shall be covered with strips of 30-pound (13.6 kg) asphalt paper or 6-mil (0.15 mm) polyethylene to. Instead of a complete geotechnical evaluation, when top or subsoils are compressible or shifting, they shall be removed to a depth and width sufficient to assure stable moisture content in each active zone and shall not be used as fill or stabilized within each active zone by chemical, dewatering or presaturation. Sixty-mil (1.5 mm) flexible polymer cement. Plan Analyst Deck, Sign and Beam & Column Calculators are additional simple and effective design and code review software tools that will quickly become your go-to resources when working on associated tasks. Decks less than 30 high (measured from grade) do not require a Building Permit. Vertical reinforcement shall be located to provide a cover of 1.25 inches measured from the inside face of the wall. REScheck product enables builders, designers, and contractors to determine whether new homes, additions, and alterations meet the requirements of the IECC or a number of state energy codes. (1); Constructing in accordance with ASCE 32; or, Foundation anchorage, spaced as required to provide equivalent anchorage to. Extended below the frost line specified in Table R301.2. For garage floors with a steel troweled finish, reduction of the total air content (percent by volume of, Structural reinforcing steel shall meet the requirements of ASTM A 615, A 706 or A 996. But what does bringing a deck up-to-code look like? Today, most permits ensure that new structures adhere to the International Building Code (IBC). Backfill shall not be placed against the wall until the wall has sufficient strength and has been anchored to the floor above, or has been sufficiently braced to prevent damage by the backfill. OneStopPGH, Boards, Authorities, Commissions
We also use third-party cookies that help us analyze and understand how you use this website. Vertical insulation shall be expanded polystyrene insulation or extruded polystyrene insulation. If your deck is considered up-to-code, you will receive a permit, although you may be given a fine. There is a list of applicable codes on L&I's website. 1. In areas where hazard of termite damage is very heavy in accordance with. Alternative reinforcing bar sizes and spacings having an equivalent cross-sectional area of reinforcement per lineal foot of wall shall be permitted provided the spacing of the reinforcement does not exceed 72 inches. Use of pier and curtain wall foundations shall be permitted to support. Pennsylvania Bulletin outlines the changes that will occur in the Regulations. Decks NOT Requiring a Building Permit Uncovered deck where the floor of the deck is no more than 30" (762 mm) above grade. If you attempt to build a deck without a permit, you run the risk of doing physical and economic harm to yourself and your community. NOTE: This guide requires a minimum post size of 6 x 6. The RAC is charged to review the periodic changes to the revised ICC codes prior to adoption into the UCC. City Clerk's Office
There are processes in place for getting an unpermitted deck up-to-code, but the process can be very unpleasant. Wood columns shall not be less in nominal size than 4 inches by 4 inches (102 mm by 102 mm). Table values are based on reinforcing bars with a minimum yield strength of 60,000 psi. Users of Plan Analyst in Pennsylvania have included: Visit the U.S. Department of Energy website to see the latest on energy code adoption in Pennsylvania, including the use of COMcheck and REScheck Energy Code compliance software. Adoption of the 2018 Editions of the Guidelines for, Pennsylvania Bulletin Volume 48 Number 39, Pennsylvania Department of Labor & Industry, UCC Administration and Enforcement regulation, Department of Labor & Industry, Uniform Construction Code, Chapter 3 Use and Occupancy Classification, Chapter 5 General Building Heights and Areas, Chapter 39 Power and Lighting Distribution, Section 1006 Number of Exits and Exit Access Doorways, http://www.dli.pa.gov/ucc/pages/default.aspx, https://www.osfc.pa.gov/Pages/default.aspx, https://www.health.pa.gov/topics/facilities/safety/Pages/Building%20Safety.aspx. Most jurisdictions follow the International Building Code, which devotes one sectionR507to deck construction. The UCC Administration and Enforcement regulation adopted the 2018 International Building Code and the 2018 International Residential Code (code for one- and two-family dwellings no more than 3 stories in height) throughout Pennsylvania (effective date February 14, 2022). Where a design or construction contract is signed before this effective date, application may be made and permit issued under the Uniform Construction Code (UCC) in effect at the time of contract as long as application is made August 14, 2022 or before. UpCodes offers a consolidated resource of construction and building code grouped by jurisdiction. The American Wood Council's "Design for Code Acceptance #6 - Prescriptive Residential Wood Deck Construction Guide" is a valuable resource that can be used to show code compliance for residential wooden decks. 2022 CODE CHANGES (2018 I-CODES ADOPTION) Residential Building Permits . Even if you are building your deck for your own use and you have no plans to sell your home in the foreseeable future, the record of the permit will be filed. Stair location, geometry and all railings and/or guarding. Building code officials and inspectors are not permitted to enter your home, accessory structures, or . Plan Analyst code compliance software programs make it easy for building officials, architects and other designers to quickly perform commercial and residential building code plan reviews / code studies. Integrous Fences and Building codes are in place to ensure safety, and virtually every state and municipality enforces codes for deck construction. Some building codes require inspections while building is in process while others only require an inspection after the work is done. Soils with a low potential expansion typically have a plasticity index (PI) of 0 to 15, soils with a medium potential expansion have a PI of 10 to 35 and soils with a high potential expansion have a PI greater than 20. Codes; Features. Weekdays: 7AM4PM Grout used for bedding precast foundations placed upon, Where minimum footing width is 12 inches, use of a single wythe of. Search a chapter, section, or keyword in the search bar. The edges of the vapor retarder shall extend at least 6 inches (152 mm) up the stem wall and shall be attached and sealed to the stem wall; and. may not administer and enforce the International Uncovered deck where the floor of the deck is no more than 30" (762 mm) above grade. Note: Will require Zoning Approval. Deck Railing Codes This is not to say that you are hiding the fact that you have an unpermitted deck; it is just that you will need to go through the same steps from the beginning again. (2) Outside stairs shall only serve as an exit for floors three or fewer stories above grade. changes meet the Uniform Construction Codes minimum This set of requirements ensures that anyone can access your deck easily and safely. (1) and, Where reinforcement is required by this code to terminate with a standard hook, the hook shall comply with, Requirements for installation of masonry veneer, stucco and other wall coverings on the exterior of. Perforated sheet metal plates not less than 0.070 inch (1.8 mm) thick. Code Compare. Crushed stone shall be angular in nature and meet ASTM C 33, with the maximum size stone not to exceed. These pages provide information regarding Pennsylvania's statewide building code, generally known as the Uniform Construction Code (UCC). DR means design is required in accordance with the applicable building code, or where there is no code, in accordance with . Hardware cloth of 0.035 inch (0.89 mm) wire or heavier. Slabs on ground with turned down footings shall have a minimum of one No. These acts amend the Pennsylvania Construction Code Act.